OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0.94 for '30second Chair-Stand' test, respectively. ICC values for intrarater reliability were 0.95 and 0.96 for the timed 'Up & Go' test and 0.87 and 0.91 for '30second Chair-Stand' test, respectively. Heteroscedasticity was observed in the timed 'Up & Go' test. Interrater SEM95% ranged from 9.8% to 14.2% with corresponding SRD% of 13.9-20.1%. Intrarater SEM95% ranged from 15.8% to 18.7% with corresponding SRD% of 22.3-26.5%. For '30second Chair-Stand' test interrater SEM95 ranged between 1.5 and 1.9 repetitions with corresponding SRD of 2 and 3 and intrarater SEM95 ranged between 1.8 and 2.0 repetitions with corresponding SRD values of 3. CONCLUSION: Excellent reliability was observed for the timed 'Up & Go' test and the '30second Chair-Stand' test in hospitalised stroke patients. The thresholds to detect a real change in performance were 18.7% for the timed 'Up & Go' test and 2.0 repetitions for the '30second Chair-Stand' in groups of patients and 26.5% and 3 repetitions in individual patients, respectively.
Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke.
中风住院患者计时“起立行走”测试和“30秒椅子站立”测试的绝对可靠性和相对可靠性
阅读:4
作者:Lyders Johansen Katrine, Derby Stistrup Rikke, Skibdal Schjøtt Camilla, Madsen Jacqueline, Vinther Anders
| 期刊: | PLoS One | 影响因子: | 2.600 |
| 时间: | 2016 | 起止号: | 2016 Oct 31; 11(10):e0165663 |
| doi: | 10.1371/journal.pone.0165663 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。