Development and validation of an LC‒MS/MS method for the determination of cyclocreatine phosphate and its related endogenous biomolecules in rat heart tissues.

阅读:5
作者:Abo-Elmagd Ibrahim F, Mahmoud Amr M, Al-Ghobashy Medhat A, Nebsen Marianne, Rabie Mostafa A, Mohamed Ahmed F, Ahmed Lamiaa A, El Sayed Nesrine S, Arafa Reem K, Todd Robert, Elgebaly Salwa A
The cardioprotective drug cyclocreatine phosphate has been awarded Food and Drug Administration-orphan drug designation for the prevention of ischemic injury to enhance cardiac graft recovery and survival in heart transplantation. Cyclocreatine phosphate is the water-soluble derivative of cyclocreatine. Estimating the levels of Cyclocreatine phosphate, Adenosine triphosphate, Creatine Phosphate, Creatine and Cyclocreatine helps us in understanding the energy state as well as evaluating the heart cells' function. The quantification of endogenous compounds imposes a challenging task for analysts because of the absence of a true blank matrix, whose use is required according to international guidelines. Recently, the International Council for Harmonization issued a new guideline that contains guidance on the validation of methods used to quantify endogenous components, such as the background subtraction approach that was employed in our current study. Specifically, we developed and validated a sensitive, reliable and accurate liquid chromatography-tandem mass spectrometry assay to determine simultaneously the levels of mentioned endogenous compounds in rat heart tissue. Tissue samples were prepared by protein precipitation extraction using water: methanol (1:1). Using Ultra Performance Liquid Chromatography, Chromatographic separation was achieved with ZORBAX Eclipse Plus C18 4.6 × 100 mm,3.5 μm column and conditions as following: ammonium acetate (pH 8.5): acetonitrile, 70:30 mobile phase, 0.7 mL/min flow rate and 25 °C temperature. Electrospray ionization mass detector with Multiple reaction monitoring mode was then employed, using both positive and negative modes, Analysis was carried out using 5.00-2000.00 ng/mL linear concentration range within 2 min for each analyte. According to Food and Drug Administration guidelines for bioanalytical methods, validation was carried out. We investigated the matrix effect, recovery efficiency and process efficiency for the analyte in neat solvent, postextraction matrix and tissue. The results stated mean percentage recoveries higher than 99%, accuracy 93.32-111.99%, and Relative Standard Deviation (RSD) below 15% within the concentration range of our study which indicated that target analytes' stability in their real matrix is sufficient under the employed experimental conditions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。