BACKGROUND: Human papillomavirus (HPV) testing has been employed by several European countries to augment cytology-based cervical screening programs. A number of research groups have demonstrated potential utility of next-generation sequencing (NGS) for HPV genotyping, with comparable performance and broader detection spectrum than current gold standards. Nevertheless, most of these NGS platforms may not be the best choice for medium sample throughput and laboratories with less resources and space. In light of this, we developed a Nanopore sequencing assay for HPV genotyping and compared its performance with cobas HPV Test and Roche Linear Array HPV Genotyping Test (LA). METHODS: Two hundred and one cervicovaginal swabs were routinely tested for Papanicolaou smear, cobas HPV Test and LA. Residual DNA was used for Nanopore protocol after routine testing. Briefly, HPV L1 region was amplified using PGMY and MGP primers, and PCR-positive specimens were sequenced on MinION flow cells (R9.4.1). Data generated in first 2âh were aligned with reference sequences from Papillomavirus Episteme database for genotyping. RESULTS: Nanopore detected 96 HPV-positive (47.76%) and 95 HPV-negative (47.26%) specimens, with 10 lacking β-globin band and not further analyzed (4.98%). Substantial agreement was achieved with cobas HPV Test and LA (κ: 0.83-0.93). In particular, Nanopore appeared to be more sensitive than cobas HPV Test for HPV 52 (nâ=â7). For LA, Nanopore revealed higher concordance for high-risk (κ: 0.93) than non-high risk types (κ: 0.83), and with similar high-risk positivity in each cytology grading. Nanopore also provided better resolution for HPV 52 in 3 specimens co-infected with HPV 33 or 58, and for HPV 87 which was identified as HPV 84 by LA. Interestingly, Nanopore identified 5 additional HPV types, with an unexpected high incidence of HPV 90 (nâ=â12) which was reported in North America and Belgium but not in Hong Kong. CONCLUSIONS: We developed a Nanopore workflow for HPV genotyping which was economical (about USD 50.77 per patient specimen for 24-plex runs), and with comparable or better performance than 2 reference methods in the market. Future prospective study with larger sample size is warranted to further evaluate test performance and streamline the protocol.
An economical Nanopore sequencing assay for human papillomavirus (HPV) genotyping.
阅读:7
作者:Chan Wai Sing, Chan Tsun Leung, Au Chun Hang, Leung Chin Pang, To Man Yan, Ng Man Kin, Leung Sau Man, Chan May Kwok Mei, Ma Edmond Shiu Kwan, Tang Bone Siu Fai
| 期刊: | Diagnostic Pathology | 影响因子: | 2.300 |
| 时间: | 2020 | 起止号: | 2020 May 6; 15(1):45 |
| doi: | 10.1186/s13000-020-00964-6 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
