BACKGROUND: EBT4 was newly released for radiotherapy quality assurance to improve the signal-to-noise ratio in radiochromic film dosimetry. It is important to know its dose-response characteristics before its use in the clinic. PURPOSE: This study aims to investigate and compare the dose-response curves of the Gafchromic EBT4 film for megavoltage and kilovoltage x-ray beams with different dose levels, scanning spatial resolutions, and sizes of region of interest (ROI). METHODS: EBT4 film (Lot#07052201) calibration strips (3.5Â ÃÂ 20Â cm(2) ) were exposed to a 10Ã10Â cm(2) open field at doses of 0, 63, 125, 500, 750, 1000Â cGy using 6Â MV photon beam. EBT4 film strips from the same lot were then exposed to each x-ray beam (6Â MV, 6Â MV FFF, 10Â MV FFF, 15Â MV, and 70Â kV) at six dose values (50, 100, 300, 600, 800, 1000Â cGy). A full sheet (25Â ÃÂ 20Â cm(2) ) of EBT4 film was irradiated at each energy with 300Â cGy for profile comparison with the treatment planning calculation. At two different spatial resolutions of 72 and 300Â dpi, each film piece was scanned three consecutive times in the center of an Epson 10000XL flatbed scanner in 48-bit color. The scanned images were analyzed using FilmQA Pro. For each scanned image, an ROI of 2Â ÃÂ 2Â cm(2) at the field center was selected to obtain the average pixel value with its standard deviation in the ROI. An additional ROI of 1Â cm diameter circle was also used to evaluate the impact of ROI shape and size, especially for FFF beams. The dose value, average dose-response value, and associated uncertainty were determined for each energy and relative responses were analyzed. The Student's t-test was performed to evaluate the statistical significance of the dose-response values with different color channels, ROI shapes, and spatial resolutions. RESULTS: The dose-response curves for the five x-ray energies were compared in three color channels. Weak energy dependence was found among the megavoltage beams. No significant differences (average â¼1.1%) were observed for all doses in this study among 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV beams, regardless of spatial resolution and color channel. However, a statistically significant difference in dose-response was observed up to 12% between 70Â kV and 6Â MV beams. CONCLUSIONS: The dose-response curves for Gafchromic EBT4 films were nearly independent of the energy of the photon beams among 6Â MV, 6Â MV FFF, 10Â MV FFF, and 15Â MV. For very low-energy photons (e.g., 70Â kV), a separate calibration from the same low-energy x-ray is necessary.
Technical note: Energy dependence of the Gafchromic EBT4 film: Dose-response curves for 70Â kV, 6Â MV, 6Â MV FFF, 10Â MV FFF, and 15Â MV x-ray beams.
阅读:3
作者:Chan Maria F, Park Jeonghoon, Aydin Resat, Lim Seng-Boh
| 期刊: | Medical Physics | 影响因子: | 3.200 |
| 时间: | 2023 | 起止号: | 2023 Jun;50(6):3738-3745 |
| doi: | 10.1002/mp.16240 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。