PURPOSE: To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa). MATERIALS AND METHODS: A CTV (clinical target volume)-to-PTV margin ranging from 15â¯mm in LR (left-right) and SI (superior-inferior) and 5-10â¯mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations. RESULTS: Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48â¯mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80â¯mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30â¯mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91â¯mm (intra) and 2.10 (inter) and 2.27â¯mm (intra), respectively. The calculated margin revealed dimensions of 4-5â¯mm in LR, 8-9â¯mm in SI and 6-7â¯mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72â¯mm (SI) for Σ and 4.17 (LR) and 3.75â¯mm (SI) for Ï compared to initial plans with 1.77 and 2.62â¯mm for Σ and 4.46 and 5.39â¯mm for Ï in LR and SI, respectively. CONCLUSION: The currently clinically used margin of 15â¯mm in LR and SI and 5-10â¯mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins.
Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.
阅读:10
作者:Böckelmann Felix, Putz Florian, Kallis Karoline, Lettmaier Sebastian, Fietkau Rainer, Bert Christoph
| 期刊: | Strahlentherapie Und Onkologie | 影响因子: | 2.500 |
| 时间: | 2020 | 起止号: | 2020 Jul;196(7):647-656 |
| doi: | 10.1007/s00066-020-01596-x | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
