PURPOSE: To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa). MATERIALS AND METHODS: A CTV (clinical target volume)-to-PTV margin ranging from 15â¯mm in LR (left-right) and SI (superior-inferior) and 5-10â¯mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations. RESULTS: Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48â¯mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80â¯mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30â¯mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91â¯mm (intra) and 2.10 (inter) and 2.27â¯mm (intra), respectively. The calculated margin revealed dimensions of 4-5â¯mm in LR, 8-9â¯mm in SI and 6-7â¯mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72â¯mm (SI) for Σ and 4.17 (LR) and 3.75â¯mm (SI) for Ï compared to initial plans with 1.77 and 2.62â¯mm for Σ and 4.46 and 5.39â¯mm for Ï in LR and SI, respectively. CONCLUSION: The currently clinically used margin of 15â¯mm in LR and SI and 5-10â¯mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins.
Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.
阅读:4
作者:Böckelmann Felix, Putz Florian, Kallis Karoline, Lettmaier Sebastian, Fietkau Rainer, Bert Christoph
| 期刊: | Strahlentherapie Und Onkologie | 影响因子: | 2.500 |
| 时间: | 2020 | 起止号: | 2020 Jul;196(7):647-656 |
| doi: | 10.1007/s00066-020-01596-x | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。
