Detection of Mucorales antigen in bronchoalveolar lavage samples using a newly developed lateral-flow device

利用新开发的侧向流动装置检测支气管肺泡灌洗液样本中的毛霉菌抗原

阅读:2

Abstract

A murine IgG2b monoclonal antibody, named TG11, binding to an extracellular polysaccharide antigen secreted by all Mucorales fungi has been recently developed and integrated into a lateral-flow device (TG11-LFD). The aim of this study was to establish the clinical performance of TG11-LFD on bronchoalveolar lavage (BAL) fluids for the diagnosis of mucormycosis. Thirteen BAL samples from 13 patients with mucormycosis, all of which tested positive for Mucorales qPCR (Mucor/Rhizopus [n = 5], Lichtheimia [n = 2], Rhizomucor [n = 5], and Cunninghamella [n = 1]), were used to assess the TG11-LFD. We also selected 49 BAL samples from 25 patients with other invasive fungal infections (IFI) (aspergillosis, Pneumocystis infection, candidiasis, and possible IFI) and from 20 patients without IFI for use as negative controls. The intensities of the test and control lines were recorded using a Cube reader. The diagnostic performance was assessed by analyzing the receiver operating characteristics (ROC) curve with the Jamovi software package (version 2.6.13). The area under the curve of the ROC curve was 0.739. Using a threshold value positivity ≤531 artificial units, the TG11-LFD test has a sensitivity and specificity of 76.92% and 75.51%, respectively, a positive predictive value of 45.45%, and a negative predictive value of 92.5%. In this study, we evaluated the performance of TG11-LFD on clinical samples for the first time and demonstrated its significant potential for enhancing the rapid detection of mucormycosis. Combining antigen detection with qPCR, as successfully applied in the diagnosis of aspergillosis, is likely to yield the most reliable diagnostic approach.IMPORTANCEMucormycosis is a severe emerging, invasive fungal disease caused by fungi in the order Mucorales. The mortality rate remains high at approximately 50%. Rapid diagnosis and prompt initiation of targeted treatment are associated with an improved prognosis. Gold standard diagnostic procedures have poor sensitivity and long turnaround times. Mucorales polymerase chain reaction in blood and respiratory samples has improved diagnosis, but this technique is not widely available due to high costs and the need for specialist equipment. A prototype lateral-flow device (TG11-LFD) incorporating a mouse monoclonal antibody, which binds to an extracellular polysaccharide antigen specific to Mucorales fungi, has been recently developed. In this study, we evaluated for the first time the performance of the TG11-LFD test on clinical bronchoalveolar lavage fluids for diagnosing mucormycosis. With 76.92% sensitivity and 75.51% specificity, this innovative, simple, and affordable approach shows great potential for improving the rapid diagnosis of mucormycosis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。