New Method for Measuring Statistical Distributions of Partial Discharge Pulses

测量局部放电脉冲统计分布的新方法

阅读:1

Abstract

A new digital detection system is described for measuring pulsating partial discharges (PDs). The PD detection system can continuously record all PD pulses that occur over extended periods of time, with a minimum inter-pulse time separation of 6 μs and a vertical amplitude resolution of 12 bits. Earlier PD detection systems detected PD pulse amplitude and time using complex custom-designed hardware while the present system continuously records the complete electrical waveform that carries the PD pulses using a commercial data acquisition board and extracts, in real time, the time and amplitude information of all PD pulses in software. The current approach considerably reduces the development and maintenance cost of the PD detection system, significantly increases the system portability, and may prove to be a crucial step for transferring the digital PD detection and analysis technology developed in laboratories to industry. The features of the new system are illustrated by the study of dc-excited PD pulses occurring in a point-to-plane gap in air. A new surface-mediated burst mode of PDs is discovered in which a PD pulse has a certain probability to induce another pulse. The probability is determined for several gap voltages and is found to vary strongly with the applied voltage.