The relationship of the musculocutaneous nerve to the brachial plexus evaluated by MRI

通过磁共振成像评估肌皮神经与臂丛神经的关系

阅读:1

Abstract

Axillary plexus blocks (AXB) are widely used for upper limb operations. It is recommend that AXB should be performed using a multiple injection technique. Information about the course and position of the musculocutaneous nerve (MCN) is of relevance for AXB performance. The objective of this study was to examine the position of the MCN and its relationship to the axillary sheath using MRI. 54 patients underwent an AXB with 40 ml of local anaesthetic before MRI examination. The course of the MCN and the position where it left the axillary sheath and perforated the coracobrachial muscle (MCN exit point), in relation to the axillary artery and the block needle insertion point in the axillary fold, were recorded. The MCN was seen clearly in 23, partly in 26, and not identified in five patients at the MCN exit point. The mean distance from the insertion point of the block needle in the axillary fold to the MCN exit point was 36.8 mm (SD = 18.9, range: 0-90.5). In 37 patients the MCN exit point was positioned inside the Q(1) quadrant (lateral anterior to the axillary artery) and in 11 patients inside the Q(2) quadrant (medial anterior to the axillary artery). There is a wide variability as to where the musculocutaneous nerve (MCN) leaves the axillary sheath. Therefore multiple injection techniques, or the use of a proximally directed catheter, should be appropriate to block the MCN.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。