Port-site incisional hernia from an 8-mm robotic trocar following robot-assisted radical cystectomy: Report of a rare case

机器人辅助根治性膀胱切除术后,8mm机器人套管针穿刺口切口疝:一例罕见病例报告

阅读:2

Abstract

INTRODUCTION: Port-site incisional hernia is a rare but well-known complication following a laparoscopic procedure and it may cause severe adverse outcomes, such as intestinal necrosis. Here, we report a rare case of hernia that occurred from an 8-mm trocar after robot-assisted radical cystectomy. CASE PRESENTATION: An 80-year-old woman was diagnosed with cT2bN1M0 bladder cancer. She underwent robot-assisted radical cystectomy. Nine days after surgery, she complained of severe abdominal pain. Computed tomography showed herniation of small intestine. Emergency explorative laparotomy revealed herniation of small intestine from an 8-mm trocar site. A section of the small bowel was necrotic and was resected. CONCLUSION: It is debatable whether we should routinely close the fascia of an 8-mm trocar site. The patient was an elderly woman with multiple major abdominal surgery histories and hernia risk factors. For these patients, fascial closure of the 8-mm trocar site may be indicated.