Noninvasive electrocardiographic assessment of ventricular activation and remodeling response to cardiac resynchronization therapy

无创心电图评估心脏再同步治疗后心室激活和重塑反应

阅读:2

Abstract

BACKGROUND: Cardiac resynchronization therapy (CRT) produces acute changes in electric resynchronization that can be measured noninvasively with electrocardiographic body surface mapping (ECGi). The relation between baseline acute electrophysiology metrics and their manipulation with CRT and reverse remodeling is unclear. OBJECTIVE: To test (ECGi) derived parameters of electrical activation as predictors of volumetric response to CRT. METHODS: ECGi was performed in 21 patients directly following CRT implant. Activation parameters (left ventricular total activation time [LVtat], global biventricular total activation time [VVtat], global left/right ventricular electrical synchrony [VVsync], and global left ventricular dispersion of activation times [LVdisp]) were measured at baseline and following echocardiographically optimized CRT. Remodeling response (>15% reduction left ventricular end-systolic volume) was assessed 6 months post CRT. RESULTS: Patients were aged 68.9 ± 12.1 years, 81% were male, and 57% were ischemic. Baseline measures of dyssynchrony were more pronounced in left bundle branch block (LBBB) vs non-LBBB. ECGi demonstrated a trend of greater interventricular dyssynchrony between responders and nonresponders that did not reach statistical significance (VVsync: -45.7 ± 22.4 ms vs -25.1 ± 29.3 ms, P = .227). Remaining activation parameters were similar between responders and nonresponders (VVtat 101 ± 22.0 ms vs 98.9 ± 23.4 ms, P = .838; LVtat 86.4 ± 17.1 ms vs 85.1 ± 27.7 ms, P = .904; LVdisp 28.2 ± 6.3 ms vs 27.0 ± 8.7 ms, P = .726). In volumetric responders activation parameters were significantly improved with CRT compared to nonresponders: VV sync (-45.67 ± 22.41 ms vs 2.33±18.87 ms, P = .001), VVtat (101 ± 22.04 ms vs 71 ± 14.01 ms, P = .002), LVtat (86.44 ± 17.15 ms vs 67.67 ± 11.31 ms, P = .006), and LVdisp (28.22 ± 6.3 ms vs 21.56 ± 4.45 ms, P = .008). CONCLUSION: Baseline ECGi activation times did not predict CRT volumetric response. Volumetric responders exhibited significant improvements in ECGi-derived metrics with CRT. ECGi does not select CRT candidates but may be a useful adjunct to guide left ventricle lead implants and to perform postimplant CRT optimization.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。