In vivo cardiac diffusion-weighted magnetic resonance imaging: quantification of normal perfusion and diffusion coefficients with intravoxel incoherent motion imaging

体内心脏弥散加权磁共振成像:利用体素内不相干运动成像技术量化正常灌注和弥散系数

阅读:1

Abstract

OBJECTIVES: Diffusion-weighted imaging (DWI) and the introduction of the intravoxel incoherent motion (IVIM) model have provided a unique method for evaluating perfusion and diffusion within a tissue without the need for a contrast agent. Despite its relevance, cardiac DWI has thus far been limited by low b values because of signal loss induced by physiological motion. The goal of this study was to develop a methodology for estimating IVIM parameters of in vivo cardiac magnetic resonance imaging using an efficient DWI acquisition framework. This was achieved by investigating various acquisition strategies (principal component analysis [PCA] filtering and temporal maximum intensity projection [PCATMIP] and single trigger delay [TD]) and fitting methods. MATERIAL AND METHODS: Simulations were performed on a synthetic dataset of diffusion-weighted signal intensity (SI) to determine the fitting method that would yield IVIM parameters with the greatest accuracy. The required number of b values to correctly estimate IVIM parameters was also investigated. Breath-hold DWI scans were performed for 12 volunteers to collect several TD values during diastole. Thirteen b values ranging from 0 to 550 s/mm were used. The IVIM parameters derived using the data from all the acquired TDs (PCATMIP technique) were compared with those derived using a single acquisition performed at an optimized diastolic time point (1TD). RESULTS: The main result of this study was that PCATMIP, when combined with a fitting model that accounted for T1 and T2 relaxation, provided IVIM parameters with less variability. However, an acquisition performed with 1 optimized diastolic TD provided results that were as good as those provided using PCATMIP if the R-R variability during the acquisition was sufficiently low (± 5%). Furthermore, the use of only 9 b values (that could be acquired in 2 breath-holds), instead of 13 b values (requiring 3 breath-holds), was sufficient to determine the IVIM parameters. CONCLUSIONS: This study demonstrates that IVIM is technically feasible in vivo and reports for the first time the perfusion fraction, f, and the diffusion coefficients, D and D*, for the cardiac DWI of healthy volunteers. Motion-induced signal loss, which is the main problem associated with cardiac DWI, could be avoided with the combined use of sliding acquisition during the cardiac cycle and image postprocessing with the PCATMIP algorithm. This study provides new perspectives for perfusion imaging without a contrast agent and demonstrates that IVIM parameters can act as promising tools to further characterize microvascular abnormalities or dysfunction.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。