Comparing the quantitative fit-testing results of half-mask respirators with various skin barriers in a crossover study design: a pilot study

采用交叉研究设计,比较不同皮肤屏障下半面罩呼吸器的定量密合性测试结果:一项初步研究

阅读:1

Abstract

BACKGROUND: Clinicians around the world are experiencing skin breakdown due to the prolonged usage of masks while working long hours to treat patients with COVID-19. The skin damage is a result of the increased friction and pressure at the mask-skin barrier. Throughout the COVID-19 pandemic, clinicians have been applying various skin barriers to prevent and ameliorate skin breakdown. However, there are no studies to our knowledge that assess the safety and efficacy of using these skin barriers without compromising a sufficient mask-face seal. AIM: To conduct the largest study to date of various skin barriers and seal integrity with quantitative fit testing (QNFT). METHODS: This pilot study explored whether the placement of a silicone scar sheet (ScarAway®), Cavilon™, or Tegaderm™ affects 3M™ half-face mask respirator barrier integrity when compared to no barrier using QNFT. Data were collected from nine clinicians at an academic level 1 trauma centre in New Jersey. FINDINGS: The silicone scar sheet resulted in the lowest adequate fit, whereas Cavilon provided the highest fit factor when compared to other interventions (P < 0.05). CONCLUSION: These findings help inform clinicians considering barriers for comfort when wearing facemasks during the COVID-19 pandemic and for future pandemics.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。