Accuracy of Billing Codes Used in the Therapeutic Care of Diabetic Retinopathy

糖尿病视网膜病变治疗中使用的计费代码的准确性

阅读:1

Abstract

IMPORTANCE: Insurance billing claim databases represent a growing field of scientific inquiry within ophthalmology. Validating the accuracy of billing claim codes used during the care of diabetic retinopathy is a necessary precursor to fully understanding the underlying data and subsequent results of these types of studies. OBJECTIVE: To determine the accuracy of diagnostic, procedural, and therapeutic billing codes used in the treatment of diabetic retinopathy. DESIGN, SETTING, AND PARTICIPANTS: This retrospective medical record review was conducted at 3 clinical practices (1 academic and 2 private). Insured patients with diabetic retinopathy were seen by the practices between 2011 and 2013. Each patient then had every visit for 2 years reviewed twice, once for billing data and the second for data from the medical record. Data were collected and analyzed from October 2015 to July 2016. MAIN OUTCOMES AND MEASURES: The positive predictive value (PPV) and negative predictive value (NPV) for each code of interest. Sensitivity and specificity were secondary outcomes. RESULTS: A total of 146 patients (mean [SD] age, 60.3 [12.5] years) from 11 physicians had 1072 encounters reviewed over 2 calendar years. Among the included patients, 49.3% were female (n = 72), 48.6% were white (n = 71), 37.0% were black (n = 54), and 18.5% had type 1 diabetes and a mean (SD) hemoglobin A1C level of 7.7% (1.8) (n = 27). Nearly all codes of interest that were used frequently also had a high PPV (range, 89.5%-100%) and NPV (88.6%-100%) including billing codes for intravitreal injection, focal laser, panretinal photocoagulation, laterality of procedure, ranibizumab, bevacizumab, fundus photographs, fluorescein angiography, and optical coherence tomography. Codes that were used infrequently (<20 instances) but still had a high PPV (all 100%) and NPV (99.7%-100%) were codes for aflibercept, triamcinolone, and the dexamethasone implant. Only the codes for infrequently used B-scan ultrasonography (PPV, 69.6%) and subtenon injection (PPV, 100%; NPV, 99.7%, but sensitivity of only 40%) were found to be of questionable accuracy. Other than subtenon injection (40%), all codes were also found to have a high sensitivity (range, 87.6%-100%) and a high specificity (range, 97.2%-100%). CONCLUSIONS AND RELEVANCE: These data suggest diagnostic, procedure, and therapeutic codes derived from insurance billing claims accurately reflect the medical record for patients with diabetic retinopathy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。