A Deep Learning Approach for Managing Medical Consumable Materials in Intensive Care Units via Convolutional Neural Networks: Technical Proof-of-Concept Study

基于卷积神经网络的重症监护室医疗耗材管理深度学习方法:技术概念验证研究

阅读:1

Abstract

BACKGROUND: High numbers of consumable medical materials (eg, sterile needles and swabs) are used during the daily routine of intensive care units (ICUs) worldwide. Although medical consumables largely contribute to total ICU hospital expenditure, many hospitals do not track the individual use of materials. Current tracking solutions meeting the specific requirements of the medical environment, like barcodes or radio frequency identification, require specialized material preparation and high infrastructure investment. This impedes the accurate prediction of consumption, leads to high storage maintenance costs caused by large inventories, and hinders scientific work due to inaccurate documentation. Thus, new cost-effective and contactless methods for object detection are urgently needed. OBJECTIVE: The goal of this work was to develop and evaluate a contactless visual recognition system for tracking medical consumable materials in ICUs using a deep learning approach on a distributed client-server architecture. METHODS: We developed Consumabot, a novel client-server optical recognition system for medical consumables, based on the convolutional neural network model MobileNet implemented in Tensorflow. The software was designed to run on single-board computer platforms as a detection unit. The system was trained to recognize 20 different materials in the ICU, while 100 sample images of each consumable material were provided. We assessed the top-1 recognition rates in the context of different real-world ICU settings: materials presented to the system without visual obstruction, 50% covered materials, and scenarios of multiple items. We further performed an analysis of variance with repeated measures to quantify the effect of adverse real-world circumstances. RESULTS: Consumabot reached a >99% reliability of recognition after about 60 steps of training and 150 steps of validation. A desirable low cross entropy of <0.03 was reached for the training set after about 100 iteration steps and after 170 steps for the validation set. The system showed a high top-1 mean recognition accuracy in a real-world scenario of 0.85 (SD 0.11) for objects presented to the system without visual obstruction. Recognition accuracy was lower, but still acceptable, in scenarios where the objects were 50% covered (P<.001; mean recognition accuracy 0.71; SD 0.13) or multiple objects of the target group were present (P=.01; mean recognition accuracy 0.78; SD 0.11), compared to a nonobstructed view. The approach met the criteria of absence of explicit labeling (eg, barcodes, radio frequency labeling) while maintaining a high standard for quality and hygiene with minimal consumption of resources (eg, cost, time, training, and computational power). CONCLUSIONS: Using a convolutional neural network architecture, Consumabot consistently achieved good results in the classification of consumables and thus is a feasible way to recognize and register medical consumables directly to a hospital's electronic health record. The system shows limitations when the materials are partially covered, therefore identifying characteristics of the consumables are not presented to the system. Further development of the assessment in different medical circumstances is needed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。