Assessment of Tissue Adequacy by EBUS in Conjunction with PET Scan and Operator's Experience

结合EBUS、PET扫描和操作者经验评估组织样本充足性

阅读:1

Abstract

Mediastinal lymph node assessment is a crucial step in non-small cell lung cancer staging. Positron emission tomography (PET) has been the gold standard for the assessment of mediastinal lymphadenopathy, though it has limited specificity. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is quick, accurate, and a less invasive method for obtaining a diagnostic sample in contrast to mediastinoscopy. We performed a retrospective chart analysis of 171 patients to assess the adequacy of tissue obtained by EBUS for diagnosis and molecular profiling as well as the assessment of staging and lymph node (LN) stations diagnostic yield, in correlation to PET scan and the operator’s level of experience. A significantly increased tissue adequacy was observed based on the operators’ experience, with the highest adequacy noted in trained Interventional Pulmonologist (IP) (100%), followed by >5 years of experience (93.33%), and 88.89% adequacy with <5 years of experience (p = 0.0019). PET-CT scan 18F-fluorodeoxyglucose (FDG) uptake in levels 1, 2, and 3 LN had a tissue adequacy of 76.67%, 54.64%, and 35.56%, respectively (p = 0.0009). EBUS bronchoscopy method could be used to achieve an accurate diagnosis, with IP-trained operators yielding the best results. There is no correlation with PET scan positivity, indicating that both PET and EBUS are complementary methods needed for staging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。