Wide-field digital imaging based telemedicine for screening for acute retinopathy of prematurity (ROP). Six-year results of a multicentre field study

基于广角数字成像的远程医疗技术在早产儿急性视网膜病变(ROP)筛查中的应用:一项多中心现场研究的六年结果

阅读:1

Abstract

OBJECTIVE: To report on a 6-year experience with wide-field digital imaging based telemedicine (WFDI telemedicine) to reduce the risk for blindness from retinopathy of prematurity (ROP). METHODS: Wide-angle digital fundus cameras (RetCam 120, Massie Lab, Pleasanton, CA, USA) were installed in five neonatal intensive care units (NICUs) in Germany. All prematures at risk were screened with WFDI, and the local ophthalmologists were asked to continue binocular indirect ophthalmoscopy (BIO) according to the German guidelines. Image data were coded and transferred to the Reading Centre in Regensburg. Image evaluation and additional BIO of infants with suspected treatment-requiring ROP (STR-ROP i.e. threshold ROP zone II, prethreshold ROP zone I (type-1 ROP according to ETROP), and ROP possibly requiring treatment but not reliably classifiable from the images) were performed by paediatric ophthalmologists at the Reading Centre. ROP was classified following ICROP, ETROP, and revised ICROP criteria. Outcome measures were incidence of clinically relevant ROP (CR-ROP, i.e. any ROP up to mid-peripheral zone III,