A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions

内镜超声引导下细针穿刺与细针活检在胰腺实性病变诊断中的比较

阅读:1

Abstract

BACKGROUND AND AIMS: Endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) is the method of choice for sampling pancreatic lesions. This study compares the diagnostic accuracy and safety of FNB using a novel core needle to FNA in solid pancreatic lesions. METHODS: A retrospective review of patients in whom EUS FNA or FNB was performed for solid pancreatic lesions was conducted. Diagnostic performance was calculated based upon a dual classification system: classification 1, only malignant pathology considered a true positive, versus classification 2, atypical, suspicious, and malignant pathology considered a true positive. RESULTS: 43 patients underwent FNB compared with 51 FNA. Using classification 1, sensitivity was 74.0% versus 80.0%, specificity 100% versus 100%, and diagnostic accuracy 77.0% versus 80.0% for FNB versus FNA, respectively (all p > 0.05). Using classification 2, sensitivity was 97% versus 94.0%, specificity 100% versus 100%, and diagnostic accuracy 98.0% versus 94.0% for FNB versus FNA, respectively (all p > 0.05). FNB required significantly fewer needle passes (median = 2) compared to FNA (median = 3; p < 0.001). Adverse events occurred in two (4.5%) FNB patients compared with none in the FNA group (p > 0.05). CONCLUSION: FNA and FNB have comparable sensitivity and diagnostic accuracy. FNB required fewer passes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。