Validity and reliability of the Australian Therapy Outcome Measures - Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)

澳大利亚治疗结果测量 - 物理治疗,用于足病学的有效性和可靠性(AusTOMs-PT 用于足病学)

阅读:1

Abstract

BACKGROUND: Valid and reliable outcome measure enable measurement of health care service impact. There are limited valid and reliable outcome measures for use in podiatry practice to measure the impact of treatment. This research aimed to test the face validity of the AusTOMs for Physiotherapy (AusTOMs-PT), it's adaptability to podiatry clinical practice and the reliability of its use with podiatrists. METHODS: Stage 1 used a nominal group technique with podiatrists who worked in public and/or private settings. All podiatrists underwent self-directed training in the AusTOMs framework and measures prior to interviews or focus group discussion. Discussion was centred about transferability of the core scales of the AusTOMs-PT and an adjunct measure, AusTOMs for Occupational Therapy (AusTOMs-OT) to podiatry practice. Stage 2 used 10 case studies representative of people who had foot or ankle concerns. Podiatrists were recruited and trained in the use of the relevant AusTOMs-PT scales. Podiatrists individually scored the cases at two timepoints (1 month apart) using the six scales from the AusTOMs-PT deemed by stage 1 as relevant to podiatry. Intra and inter-rater reliability of scales were determined using intraclass correlation coefficients (ICCs). RESULTS: Thirteen podiatrists participated in individual or focus group interviews in Stage 1. Consensus was gained on six of the nine core scales adopted from the AusTOMs-PT. These were 1. Balance and Postural Control, 3. Musculoskeletal Movement Related Functions, 4. Neurological Movement Related Functions, 5. Pain, 7. Sensory Functions, 8. Skin Functions. Each core scale rated the functional domains of Impairment, Activity Limitation, Participation Restriction and Wellbeing/Distress relating to that presentation of goals of the person in the case study. There were 22 podiatrists complete training and scored two rounds of case studies using the six scales in Stage 2. There were 91%(n = 20) participants with an intra-rater ICC > 0.5 (moderate or greater). Each domain had an inter-rater reliability of > 0.9 (excellent) during the first round. CONCLUSIONS: The AusTOMs-PT for use in podiatry may be implemented to record change in impairment, function, participation and wellbeing of people receiving podiatry treatment. Podiatry specific training and mentoring, together with repeated use could be expected to improve intra-reliability.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。