Report on the Hemodialysis Reliable Outflow (HeRO) experience in dialysis patients with central venous occlusions

关于血液透析可靠流出(HeRO)技术在中心静脉阻塞透析患者中应用经验的报告

阅读:1

Abstract

OBJECTIVE: The Hemodialysis Reliable Outflow (HeRO) graft (Hemosphere/CryoLife Inc, Eden Prairie, Minn) has provided an innovative means to obtain hemodialysis access for patients with severe central venous occlusive disease. The outcomes of this novel treatment modality in a difficult population have yet to be clearly established. METHODS: A retrospective review of HeRO graft placement from June 2010 to January 2012 was performed. Patient hemodialysis access history, clinical complexity, complications, and outcomes were analyzed. Categoric data were described with counts and proportions, and continuous data with means, ranges and, when appropriate, standard deviations. Patency rates were analyzed using life-table analysis, and patency rate comparisons were made with a two-group proportion comparison calculator. RESULTS: HeRO graft placement was attempted 21 times in 19 patients (52% women), with 18 of 21 (86%) placed successfully. All but one was placed in the upper extremity. Mean follow-up after successful placement has been 7 months (range, 0-23 months). The primary indication for all HeRO graft placements except one was central vein occlusion(s) and need for arteriovenous access. Patients averaged 2.0 previous (failed) accesses and multiple catheters. Four HeRO grafts (24%), all in women, required ligation and removal for severe steal symptoms in the immediate postoperative period (P < .01 vs men). Three HeROs were placed above fistulas for rescue. All thrombosed <4 months, although the fistulas remained open. An infection rate of 0.5 bacteremic events per 1000 HeRO-days was observed. At a mean follow-up of 7 months, primary patency was 28% and secondary patency was 44%. The observed 12-month primary and secondary patency rates were 11% and 32%, respectively. Secondary patency was maintained in four patients for a mean duration of 10 months (range, 6-18 months), with an average of 4.0 ± 2.2 thrombectomies per catheter. CONCLUSIONS: HeRO graft placement, when used as a last-resort measure, has been able to provide upper extremity access in patients who otherwise would not have this option. There is a high complication rate, however, including a very high incidence of steal in women. HeRO grafts should continue to be used as a last resort.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。