Validation Study of the Chinese Version of Addenbrooke's Cognitive Examination III for Diagnosing Mild Cognitive Impairment and Mild Dementia

验证中文版艾登布鲁克认知检查III在诊断轻度认知障碍和轻度痴呆中的有效性

阅读:1

Abstract

BACKGROUND AND PURPOSE: There are only a few cognitive screening tests for the Chinese-speaking population, and so this study aimed to validate the Chinese version of Addenbrooke's Cognitive Examination III (ACE-III) for detecting mild cognitive impairment (MCI) and mild dementia. Its diagnostic accuracy was compared with the Chinese versions of the Mini Mental State Examination (MMSE) and the Montreal Cognitive Assessment (MoCA). METHODS: The 176 included individuals were divided into 3 groups: mild dementia group, MCI group, and normal control group. MMSE, MoCA, and ACE-III were administered to all participants by researchers who were blinded to the clinical grouping. The receiver operating characteristic (ROC) curves were analyzed. RESULTS: ACE-III exhibited good internal consistency and convergent validity. Age and education level significantly influenced the total ACE-III scores. When screening MCI, the area under the ROC curve (AUC) was significantly larger for ACE-III than for MMSE (0.88 vs. 0.72, p<0.05) and MoCA (0.88 vs. 0.76, p<0.05). ACE-III showed higher sensitivity (0.75) and specificity (0.89) than MMSE (0.64 and 0.63, respectively) and MoCA (0.67 and 0.77) at the optimal cutoff score of 88/89. For detecting mild dementia, ACE-III yielded satisfactory sensitivity (0.94) and specificity (0.83) at the optimal cutoff score of 74/75. The AUC of ACE-III was 0.95, which was comparable to those of MMSE (0.95) and MoCA (0.91). In participants with ≥12 years of education, the AUC was significantly larger for ACE-III than for MMSE when detecting MCI (0.90 vs. 0.68, p<0.05) and mild dementia (0.97 vs. 0.90, p<0.05). CONCLUSIONS: The present study has verified that ACE-III is a reliable and accurate tool for screening MCI and mild dementia in the Chinese-speaking population, and is significantly superior to MMSE and MoCA for detecting MCI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。