Coronary Stent Fracture Causing Myocardial Infarction: Case Report and Review of Literature

冠状动脉支架断裂导致心肌梗死:病例报告及文献综述

阅读:1

Abstract

Coronary stent fracture (SF) is a potential cause of stent failure increasing the risk for in-stent restenosis, stent thrombosis, target lesion revascularization and major adverse cardiac events. Overall incidence of SF ranges from  <  1.0% up to 18.6% and SF can be found in up to 60% of failed devices. Advanced imaging techniques have improved the detection of SF. However, defining the optimal therapeutic approach towards these complex lesions is challenging. This review summarizes the most important publications on the topic of SF and discusses current insights into pathophysiology, diagnostic tools, classification and therapeutic management. Furthermore, two illustrative cases of SF leading to myocardial infarction are presented, which demonstrate typical SF risk factors such as vessel angulation and hinge motion, stenting in the right coronary artery, use of long stents and multiple stent layers.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。