Why Is a b-value Range of 1500-2000 s/mm² Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

为什么在合成扩散加权成像中评估前列腺指数病灶时,b 值范围为 1500-2000 s/mm² 是最佳的?

阅读:1

Abstract

OBJECTIVE: It is uncertain why a b-value range of 1500-2000 s/mm² is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. MATERIALS AND METHODS: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm² using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm². We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. RESULTS: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm² and 1640-1771 s/mm² (median, 1790 s/mm² vs. 1705 s/mm²; p = 0.003) for reader 1, and 1835-1895 s/mm² and 1705-1841 s/mm² (median, 1872 s/mm² vs. 1763 s/mm²; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm² and 1573-1867 s/mm² for reader 1, and 1775-1945 s/mm² and 1591-1955 s/mm² for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm² between qualitatively and quantitatively selected optimal b-values. CONCLUSION: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm².

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。