Iatrogenic rupture of the ureter during kidney biopsy

肾活检术中医源性输尿管破裂

阅读:1

Abstract

Perirenal hematoma, hematuria, and abdominal pain are common complications of kidney biopsy, but ureter rupture is relatively less frequent. Here we report a patient who experienced severe abdominal pain and gross hematuria following a non-smooth procedure of ultrasound-guided kidney biopsy. Computed tomography showed rupture of the left upper third of the ureter. We implanted a curled double-J catheter between the renal pelvis and urinary bladder. Abdominal pain and gross hematuria improved. After 2 months, the double-J catheter was removed and the patient had no further clinical symptoms. The possibility of ureter rupture, although rare, should be considered in the presence of abdominal pain and gross hematuria in patients after receiving a kidney biopsy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。