Factors affecting pediatric isotonic fluid resuscitation efficiency: a randomized controlled trial evaluating the impact of syringe size

影响儿童等渗液体复苏效率的因素:一项评估注射器尺寸影响的随机对照试验

阅读:1

Abstract

BACKGROUND: Goal-directed therapy guidelines for pediatric septic shock resuscitation recommend fluid delivery at speeds in excess of that possible through use of regular fluid infusion pumps. In our experience, syringes are commonly used by health care providers (HCPs) to achieve rapid fluid resuscitation in a pediatric fluid resuscitation scenario. At present, it is unclear which syringe size health care providers should use when performing fluid resuscitation to achieve maximal fluid resuscitation efficiency. The objective of this study was therefore to determine if an optimal syringe size exists for conducting manual pediatric fluid resuscitation. METHODS: This 48-participant parallel group randomized controlled trial included 4 study arms (10, 20, 30, 60 mL syringe size groups). Eligible participants were HCPs from McMaster Children's Hospital, Hamilton, Canada blinded to the purpose of the trial. Consenting participants were randomized using a third party technique. Following a standardization procedure, participants administered 900 mL (60 mL/kg) of isotonic saline to a simulated 15 kg child using prefilled provided syringes of the allocated size in rapid sequence. Primary outcome was total time to administer the 900 mL and this data was collected through video review by two blinded outcome assessors. Sample size was predetermined based upon a primary outcome analysis using one-way ANOVA. RESULTS: 12 participants were randomized to each group (n=48) and all completed trial protocol to analysis. Analysis was conducted according to intention to treat principles. A significant difference in fluid resuscitation time (in seconds) was found between syringe size group means: 10 mL, 563s [95% CI 521; 606]; 20 mL, 506s [95% CI 64; 548]; 30 mL, 454s [95% CI 412; 596]; 60 mL, 455s [95% CI 413; 497] (p<0.001). CONCLUSIONS: The syringe size used when performing manual pediatric fluid resuscitation has a significant impact on fluid resuscitation speed, in a setting where fluid filled syringes are continuously available. Greatest efficiency was achieved with 30 or 60 mL syringes. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01494116.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。