A complex four-point method for the evaluation of ohmic and faradaic losses within a redox flow battery single-cell

一种用于评估氧化还原液流电池单电池中欧姆损耗和法拉第损耗的复杂四点法

阅读:1

Abstract

We propose a complex 4-point method for characterization of flow batteries. The distribution of ohmic and faradaic losses within a single-cell is evaluated from electrochemical impedance spectra and load curves of positive and negative half-cells measured with platinum wire pseudo-reference electrodes positioned in respective electrode compartment. The developed method can be used e.g., for the component screening and in-situ durability studies on single-cell scale. The method was validated on a vanadium redox flow battery single-cell; however, it can be analogically employed for various chemistries of flow battery. •Complex 4-point method for characterization of flow battery single-cell was developed.•Method is based on electrochemical impedance spectra and load curve measurements.•Direct evaluation of ohmic and faradaic losses distribution within battery single-cell by the method.