Accurate episomal HIV 2-LTR circles quantification using optimized DNA isolation and droplet digital PCR

利用优化的DNA分离和液滴数字PCR技术,对游离型HIV 2-LTR环状DNA进行精确定量。

阅读:1

Abstract

INTRODUCTION: In HIV-infected patients on combination antiretroviral therapy (cART), the detection of episomal HIV 2-LTR circles is a potential marker for ongoing viral replication. Quantification of 2-LTR circles is based on quantitative PCR or more recently on digital PCR assessment, but is hampered due to its low abundance. Sample pre-PCR processing is a critical step for 2-LTR circles quantification, which has not yet been sufficiently evaluated in patient derived samples. MATERIALS AND METHODS: We compared two sample processing procedures to more accurately quantify 2-LTR circles using droplet digital PCR (ddPCR). Episomal HIV 2-LTR circles were either isolated by genomic DNA isolation or by a modified plasmid DNA isolation, to separate the small episomal circular DNA from chromosomal DNA. This was performed in a dilution series of HIV-infected cells and HIV-1 infected patient derived samples (n=59). Samples for the plasmid DNA isolation method were spiked with an internal control plasmid. RESULTS: Genomic DNA isolation enables robust 2-LTR circles quantification. However, in the lower ranges of detection, PCR inhibition caused by high genomic DNA load substantially limits the amount of sample input and this impacts sensitivity and accuracy. Moreover, total genomic DNA isolation resulted in a lower recovery of 2-LTR templates per isolate, further reducing its sensitivity. The modified plasmid DNA isolation with a spiked reference for normalization was more accurate in these low ranges compared to genomic DNA isolation. A linear correlation of both methods was observed in the dilution series (R2=0.974) and in the patient derived samples with 2-LTR numbers above 10 copies per million peripheral blood mononuclear cells (PBMCs), (R2=0.671). Furthermore, Bland-Altman analysis revealed an average agreement between the methods within the 27 samples in which 2-LTR circles were detectable with both methods (bias: 0.3875±1.2657 log10). CONCLUSIONS: 2-LTR circles quantification in HIV-infected patients proved to be more accurate with a modified plasmid DNA isolation procedure compared to total genomic DNA isolation. This method enables the processing of more blood cells, thus enhancing quantification accuracy and sensitivity. An improved quantification of 2-LTR circles will contribute to the better understanding of ongoing replication in the HIV reservoir of patients on cART.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。