Use of wound dressings to enhance prevention of pressure ulcers caused by medical devices

使用伤口敷料加强预防医疗器械引起的压疮

阅读:2

Abstract

Medical device related pressure ulcers (MDR PUs) are defined as pressure injuries associated with the use of devices applied for diagnostic or therapeutic purposes wherein the PU that develops has the same configuration as the device. Many institutions have reduced the incidence of traditional PUs (sacral, buttock and heel) and therefore the significance of MDR PU has become more apparent. The highest risk of MDR PU has been reported to be patients with impaired sensory perception, such as neuropathy, and an impaired ability for the patient to communicate discomfort, for example, oral intubation, language barriers, unconsciousness or non-verbal state. Patients in critical care units typify the high-risk patient and they often require more devices for monitoring and therapeutic purposes. An expert panel met to review the evidence on the prevention of MDR PUs and arrived at these conclusions: (i) consider applying dressings that demonstrate pressure redistribution and absorb moisture from body areas in contact with medical devices, tubing and fixators, (ii) in addition to dressings applied beneath medical devices, continue to lift and/or move the medical device to examine the skin beneath it and reposition for pressure relief and (iii) when simple repositioning does not relieve pressure, it is important not to create more pressure by placing dressings beneath tight devices.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。