Using a double-channel gastroscope reduces procedural time in performing gastric endoscopic submucosal dissection

使用双通道胃镜可缩短胃内镜黏膜下剥离术的手术时间。

阅读:1

Abstract

OBJECTIVE: Complications are important determining factors for safety of endoscopic submucosal dissection (ESD). ESD of large lesions is associated with increased procedural time. This study investigated whether double-channel gastroscope could be used to reduce procedural time in gastric antrum ESD. METHODS: A retrospective cohort study of 46 patients with one gastric antrum lesion resected by ESD was conducted between January 2013 and December 2015. The diameter of a lesion was from 2cm to 4cm in 46 patients. EUS before ESD was used to evaluate the submucosal vascular structure and the location of lesion in gastric wall. Forty six lesions had ESD with either the ordinary gastroscope (OS group) (n=24) or the double-channel gastroscope (DC group) (n=22). RESULTS: The mean procedural time was significantly lower in the DC group than in the OS group (49.1 minutes vs. 20.5 minutes, p=0.04). There were no significant differences in submucosal injection frequency, specimen size, en bloc resection rate and perforation rate between the two endoscopic groups. There was no recurrence in any case during the follow-up period. CONCLUSIONS: Our data suggest that ESD utilizing double-channel gastroscope may provide a better platform for quicker ESD with equal safety.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。