A proposed method of logarithmic transformation of optical coherence tomography data for use in clinical research

一种用于临床研究的光学相干断层扫描数据对数变换方法

阅读:1

Abstract

PURPOSE: To evaluate a logarithmic transformation of retinal thickness measurements from optical coherence tomography as a new approach to assess clinically meaningful changes in retinal thickness. DESIGN: Methodologic, evidence-based review. METHODS: Standard published approaches for assessing change in retinal thickness over time, as measured by optical coherence tomography (OCT), were compared with a new approach based on a logarithmic transformation of the retinal thickness data. Comparative examples were derived using published data from a clinical trial comparing intravitreal corticosteroid injections for diabetic macular edema with standard laser treatment. MAIN OUTCOME MEASURES: Comparative examples using Diabetic Retinopathy Clinical Research Network data. RESULTS: Logarithmic transformation of retinal thickness data results in a more normalized distribution of OCT data and allows for data analyses assessing proportionate changes in retinal thickness during follow-up. CONCLUSIONS: For analysis of grouped data, a logarithmic transformation of the OCT retinal thickness measurements (logOCT) provides several analytic advantages. Distributions of retinal thickness in groups of eyes with diabetic macular edema, and many other causes of macular thickening, tend to be skewed to the right; the logOCT transformation tends to normalize these distributions, which has value for statistical comparisons. For assessing whether the observed OCT change in a patient is real (and not due to testing variability), a 1-step log scale change exceeds the measurement error for all degrees of retinal thickness in current instruments. In addition, this log scale is similar to the logarithm of the minimum angle of resolution (logMAR) scale used for visual acuity. Steps on the log scale for change in thickness seem to be better related to clinical importance than the actual change in microns because each step on the log scale is the same proportionate change in thickness, with a 3-step change equaling a halving or doubling of thickness, regardless of the baseline value. Transformation of OCT retinal thickness data to logOCT may assist in the assessment of clinically meaningful changes in retinal thickness just as use of the logMAR scale has helped to assess clinically meaningful changes in visual acuity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。