Robotic video-assisted thoracoscopic surgery using multiport triangular trocar configuration: initial experience at a single center

采用多孔三角套管配置的机器人辅助胸腔镜手术:单中心初步经验

阅读:1

Abstract

BACKGROUND: Recent developments in robotic technology have brought significant changes in robotic video-assisted thoracoscopic surgery (r-VATS) worldwide, particularly including the treatment in the thorax for the mediastinal, esophagus, and pulmonary lesions. Currently, there are only a few reports describing the procedural experience and outcomes with r-VATS. The objective of this study is to provide our initial experience using r-VATS at a single center, with specific attention to safety, efficacy, and procedural details. METHODS: We retrospectively reviewed patients who underwent a newly modified r-VATS procedure for various surgical operations at the thoracic department of our hospital, from July 2018 to January 2020. Multiport trocars were placed in the classic triangular arrangement as in conventional VATS (c-VATS) but with modifications based on the type of surgery. The peri- and postoperative outcomes such as duration of surgery, complications, and duration of hospital stay for these patients were reported. RESULTS: Overall, 142 patients underwent r-VATS for lobectomy (66), wedge resection (15), thymectomy (22), mediastinal tumor resection (30), pneumonectomy (4), transthoracic esophagectomy (1), esophageal tumor resection or esophageal diverticulum repair (2), diaphragm plication (1), and mediastinal tumor resection plus thymectomy (1). For the entire cohort, the median operative time was 110 min, and the median length of hospital stay was 5 days. Conversion to open thoracic surgery was reported only in a total of 3 (2.1%) patients of pneumonectomy (1.4%) and mediastinal tumor resection (0.70%). All our patients were managed successfully with no postoperative complications and mortality. CONCLUSION: Our method of r-VATS was found to be safe and effective and may be applied to different surgical operations. Adequate and proper training of thoracic surgeons is immediately needed for the transition from c-VATS to r-VATS. The utility and advantages of triangular trocar configuration for r-VATS require further refinement and research before it can be routinely adopted in clinical practice. TRIAL REGISTRATION: Retrospectively registered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。