Development of an Enzymatic Biosensor Using Glutamate Oxidase on Organic-Inorganic-Structured, Electrospun Nanofiber-Modified Electrodes for Monosodium Glutamate Detection

利用谷氨酸氧化酶在有机-无机结构静电纺丝纳米纤维修饰电极上构建酶生物传感器用于检测谷氨酸钠

阅读:1

Abstract

Herein, dendrimer-modified montmorillonite (Mt)-decorated poly-Ɛ-caprolactone (PCL) and chitosan (CHIT)-based nanofibers were prepared. Mt was modified with a poly(amidoamine) generation 1 (PAMAM(G1)) dendrimer, and the obtained PAMAM(G1)-Mt was incorporated into the PCL-CHIT nanofiber's structure. The PCL-CHIT/PAMAM(G1)-Mt nanofibers were conjugated with glutamate oxidase (GluOx) to design a bio-based detection system for monosodium glutamate (MSG). PAMAM(G1)-Mt was added to the PCL-CHIT backbone to provide a multipoint binding side to immobilize GluOx via covalent bonds. After the characterization of PCL-CHIT/PAMAM(G1)-Mt/GluOx, it was calibrated for MSG. The linear ranges were determined from 0.025 to 0.25 mM MSG using PCL-CHIT/Mt/GluOx and from 0.0025 to 0.175 mM MSG using PCL-CHIT/PAMAMG(1)-Mt/GluOx (with a detection limit of 7.019 µM for PCL-CHIT/Mt/GluOx and 1.045 µM for PCL-CHIT/PAMAMG(1)-Mt/GluOx). Finally, PCL-CHIT/PAMAMG(1)-Mt/GluOx was applied to analyze MSG content in tomato soup without interfering with the sample matrix, giving a recovery percentage of 103.125%. Hence, the nanofiber modification with dendrimer-intercalated Mt and GluOx conjugation onto the formed nanocomposite structures was performed, and the PCL-CHIT/PAMAM(G1)-Mt/GluOx system was successfully developed for MSG detection.