The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients

桡动脉和股动脉动脉压波形心输出量测量在重大心脏手术患者中的价值

阅读:2

Abstract

BACKGROUND: A relatively new uncalibrated arterial pressure waveform cardiac output (CO) measurement technique is the Pulsioflex-ProAQT® system. Aim of this study was to validate this system in cardiac surgery patients with a specific focus on the evaluation of a difference in the radial versus the femoral arterial access, the value of the auto-calibration modus and the ability to show fluid-induced changes. METHODS: In twenty-five patients scheduled for ascending aorta, aortic arch replacement, or both we measured CO simultaneously by transpulmonary thermodilution (COtd) and by using the ProAQT® system connected to the radial (COpR), as well as the femoral artery catheter (COpF). Hemodynamic data were assessed at predefined time points; from incision until 16 h after ICU admission. RESULTS: In total 175 (radial) and 179 (femoral) pairs of CO measurement were collected. The accuracy of COpR/COpF was evaluated showing a mean bias of -0.31 L/min (±2.9 L/min) and -0.57 L/min (± 2.8 L/min) with percentage errors of 49 and 46% respectively. Trending ability of the ProAQT® device was evaluated; the four quadrant concordance rates in the radial and femoral artery were 74 and 75% and improved to 77 and 85% after auto-calibration. The mean angular biases in the radial and femoral artery were 6.4° and 6.0° and improved to 5° and 3.3° after auto-calibration. The polar concordance rates in the radial and femoral artery were 65 and 70% and improved to 76 and 84% after auto-calibration. Considering the fluid-induced changes in stroke volume(SV), the coefficient of correlation between the changes in SVtd and SVp was 0.57 (p < 0.01) in the radial artery and 0.60 (p < 0.01) in the femoral artery. CONCLUSIONS: The ProAQT® system can be of additional value if the clinician wants to determine fluid responsiveness in cardiac surgery patients. However, the ProAQT® system provided inaccurate CO measurements compared to transpulmonary thermodilution. The trending ability was poor for COpR but moderate for COpF. Auto-calibration of the system did not improve accuracy of CO measurements nor did it improve the prediction of fluid responsiveness. However, the trending ability was improved by auto-calibration, possibly by correcting a drift over a longer time period.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。