The effects of thoracic epidural analgesia on oxygenation and pulmonary shunt fraction during one-lung ventilation: an meta-analysis

胸段硬膜外镇痛对单肺通气期间氧合和肺分流率的影响:一项荟萃分析

阅读:1

Abstract

BACKGROUND: The aim of our study is to compare the effects of thoracic epidural analgesia combined with general anesthesia (GA) vs. general anesthesia on oxygenation and pulmonary shunt fraction during one-lung ventilation (OLV). METHODS: Literature research was firstly conducted for studies related to comparison of epidural anesthesia combined with GA vs. GA with reporting of hemodynamic and oxygenation variables and published from Jan 1990 to Jan 2014 in EMBAS, MEDLINE and Cochrane Central Register of Controlled Trials databases. The studies were reviewed and data were extracted and analyzed using fixed-effect and random-effect models. RESULTS: There are 14 trials with 60 separate comparisons enrolling 653 patients for analysis. Regarding systemic hemodynamics, thoracic epidural analgesia decreased the mean arterial pressure and mean pulmonary arterial pressure with weighted mean difference 95% confidence interval (-6.64 [-9.57 to -3.71] vs. -6.33 [-9.25 to -3.41] and -3.18 [-5.07 to -1.28] vs. -2.05 [-3.35 to -0.75]) respectively at the two measurements time, however, only decreasing heart rate and systemic vascular resistance (-3.28 [-5.98 to -0.67] and -319.99 [-447.05 to -192.94]) over the first 30 min after OLV. For oxygenation variables, thoracic epidural analgesia is associated with significant reduction in partial arterial oxygen pressure, mixed arterial saturation of oxygenation and increased pulmonary venous admixture fraction compared to general anesthesia with weighted mean difference 95% confidence interval (-16.52 [-21.98 to - 11.05] vs. - 14.23 [-20.81 to - 7.65]), (0.74 [0.33 to 1.15] vs. - 0.63 [-1.23 to -0.04]) and (2.53 [1.35 to 3.72] vs. 2.77 [1.81 to 3.74]) respectively before and after 30 min of one-lung ventilation. A decrease in mixed venous saturation of oxygenation occurred after 30 min of OLV (-2.39 [-3.73 to -0.99]). Besides, a higher mean value of airway pressure was found in the thoracic epidural analgesia with weighted mean difference 95% confidence interval (1.95 [1.61 to 2.28] vs. 0.87 [0.54 to 1.20]) at the measurements. CONCLUSION: Based on the existing limited data puts forward recommendations for cautious usage of thoracic epidural analgesia in case of underlying risks in lower systemic hemodynamics, decreased partial arterial oxygen pressure but increases pulmonary shunt during one-lung ventilation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。