Lithotomy versus jack-knife position on haemodynamic parameters assessed by impedance cardiography during anorectal surgery under low dose spinal anaesthesia: a randomized controlled trial

低剂量脊髓麻醉下行肛门直肠手术时,截石位与侧卧位对阻抗心动描记法评估的血流动力学参数的影响:一项随机对照试验

阅读:2

Abstract

BACKGROUND: Although the prone position providing better exposure for anorectal surgery is required it can cause a reduction of cardiac output and cardiac index. The goal was to compare haemodynamic changes assessed by impedance cardiography during anorectal surgery under low-dose spinal anaesthesia in lithotomy and jack-knife position. METHODS: The prospective randomized controlled study included 104, ASA I-II adult patients admitted for elective minor anorectal surgery, assigned to be performed in lithotomy (groupL, n = 52) or jack-knife position (groupJ, n = 52). After arrival to operating room the standard monitoring, impedance cardiography device was connected to the patient, and the following variables were recorded: cardiac output, cardiac index, systemic vascular resistance, stroke index at times of arrival to operating room, placement for, start and end of surgery and placement to bed. Spinal block was made in the sitting position with 4 mg of 0.5% hyperbaric bupivacaine and 10 μg of Fentanyl injected over 2 min. Comparison was based on haemodynamic changes between and inside groups over time. Student's t, chi square tests were used for statistical analysis with p < 0.05 regarded as statistically significant. RESULTS: The reduction of cardiac output was statistically significant after placement of the patient into the prone position: from baseline 7.4+/-1.6 to 4.9+/-1.2 after placement for and 4.7+/-1.2 at the start and end of surgery (mean +/-SD l/min). The difference of cardiac output between groups was 2.0 l/min after positioning for and the start of surgery and 1.5 l/min at the end of surgery (p < 0.05). Mean cardiac index reduced from baseline 3.9+/-0.8 to 2.6+/-0.7 and 2.4+/-0.6 (mean+/-SD l/min/m(2)) in groupJ and between groups: by 1.0 l/min/m(2) after placement for, 1.1 at the start and 0.8 at the end of surgery (p < 0.05). Systemic vascular resistance increased from baseline 1080+/-338 to 1483+/-479 after placement for, 1523+/-481 at the start and 1525+/-545 at the end of surgery in groupJ (mean+/-SD dynes/sec/cm(-5), p < 0.05). CONCLUSIONS: According to impedance cardiography, jack-knife position after low-dose spinal anaesthesia produces transitory, but statistically significant reduction of cardiac output and cardiac index with increase of systemic vascular resistance, compared to insignificant changes in lithotomy position. TRIAL REGISTRATION: Clinical Trials NCT02115178.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。