The effect of initial local anesthetic dose with continuous interscalene analgesia on postoperative pain and diaphragmatic function in patients undergoing arthroscopic shoulder surgery: a double-blind, randomized controlled trial

初始局部麻醉剂量联合持续臂丛神经间隙镇痛对肩关节镜手术患者术后疼痛和膈肌功能的影响:一项双盲随机对照试验

阅读:1

Abstract

BACKGROUND: Interscalene block (ISB) is commonly performed using 20-40 mL of local anesthetic. Spread to adjacent structures and consequent adverse effects including paralysis of the ipsilateral hemidiaphragm are frequent. Pain ratings, analgesic requirements, adverse events, satisfaction, function and diaphragmatic excursion were compared following interscalene block (ISB) with reduced initial bolus volumes. METHODS: Subjects undergoing arthroscopic rotator cuff repair were randomized to receive 5, 10, or 20 mL ropivacaine 0.75% for ISB in a double-blind fashion (N = 36). Continuous infusion with ropivacaine 0.2% was maintained for 48 h. Pain and diaphragmatic excursion were assessed before block and in the recovery unit. RESULTS: Pain ratings in the recovery room were generally less than 4 (0-10 NRS) for all treatment groups, but a statistically significant difference was noted between the 5 and 20 mL groups (NRS: 2.67 vs. 0.62 respectively; p = 0.04). Pain ratings and supplemental analgesic use were similar among the groups at 24 h, 48 h and 12 weeks. There were no differences in the quality of block for surgical anesthesia. Dyspnea was significantly greater in the 20 mL group (p = 0.041). Subjects with dyspnea had significant diaphragmatic impairment more frequently (Relative risk: 2.5; 95%CI: 1.3-4.8; p = 0.042). Increased contralateral diaphragmatic motion was measured in 29 of the 36 subjects. Physical shoulder function at 12 weeks improved over baseline in all groups (baseline mean SST: 6.3, SEM: 0.6; 95%CI: 5.1-7.5; 12 week mean SST: 8.2, SEM: 0.46; 95%CI: 7.3-9.2; p = 0.0035). CONCLUSIONS: ISB provided reliable surgical analgesia with 5 mL, 10 mL or 20 mL ropivacaine (0.75%). The 20 mL volume was associated with increased complaints of dyspnea. The 5 mL volume was associated with statistically higher pain scores in the immediate postoperative period. Lower volumes resulted in a reduced incidence of dyspnea compared to 20 mL, however diaphragmatic impairment was not eliminated. Compensatory increases in contralateral diaphragmatic movement may explain tolerance for ipsilateral paresis. TRIAL REGISTRATION: clinicaltrials.gov. identifier: NCT00672100.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。