Changes in perfusion can detect changes in the cardiac index in patients with septic shock

灌注变化可以检测脓毒性休克患者的心指数变化。

阅读:1

Abstract

OBJECTIVE: The perfusion index (PI) is usually used to assess peripheral perfusion, which can be influenced by the cardiac index (CI). CI monitoring is often needed during the treatment of patients with shock. We investigated the relationship between changes in the PI (ΔPI) and changes in the CI (ΔCI) in patients with septic shock. METHODS: This retrospective study included patients with septic shock who underwent pulse-induced continuous cardiac output monitoring. We measured the CI and PI before and after fluid loading during the first 6 hours of intensive care unit admission. Fluid responsiveness was defined as a ≥10% ΔCI after fluid loading. Other hemodynamic and oxygen-derived parameters were also collected at the exact time of each CI measurement. RESULTS: Fifty-five patients were included in the study (29 fluid responders, 26 fluid non-responders). In the univariate analysis, ΔPI was positively correlated with ΔCI. In the multivariable analysis, ΔPI was independently associated with ΔCI. The receiver operating characteristic curve showed that ΔPI was an appropriate marker with which to discriminate a CI increase with an area under the curve of 0.776. CONCLUSION: This study showed a positive correlation between ΔPI and ΔCI during the early treatment phase of septic shock.