Clinical evaluation of the T-SPOT.TB test for detection of tuberculosis infection in northeastern Guangdong Province, China

中国广东省东北部地区T-SPOT.TB检测结核病感染的临床评价

阅读:1

Abstract

OBJECTIVE: We evaluated clinical performance of the T-SPOT.TB test for detecting tuberculosis (TB) infection in Meizhou, China. METHODS: We enrolled 2,868 patients who underwent T-SPOT.TB, smear, and TB-DNA at the same time. The tests' sensitivity and specificity were evaluated and compared in different groups, and in pulmonary TB (PTB) and extrapulmonary TB (EPTB) subgroups. Receiver operator characteristic (ROC) curve analysis was used to evaluate T-SPOT.TB's diagnostic value and determine its cutoff value. RESULTS: T-SPOT.TB, TB-DNA, and sputum smear sensitivity was 61.44%, 37.12%, and 14.02%; and specificity was 76.49%, 99.20% and 99.60%, respectively. The T-SPOT.TB positive rate was higher in the PTB and EPTB subgroups than in patients with other pulmonary diseases (61.38% and 61.76% vs. 23.34%). The T-SPOT.TB test had better diagnostic accuracy and sensitivity when the positive cutoff value of marker ESAT-6 was 2.5 [area under ROC curve = 0.701, 95%CI 0.687-0.715] and marker CFP-10 was 6.5 [area under ROC curve = 0.669, 95%CI 0.655-0.683]. CONCLUSION: T-SPOT.TB sensitivity was higher than that of TB-DNA or sputum smear, but the specificity was lower. T-SPOT.TB had moderate sensitivity and specificity for diagnosing TB. T-SPOT.TB's new positive cutoff value may be clinically valuable according to ROC analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。