Analysis of a novel hydrophobic acrylic enhanced monofocal intraocular lens compared to its standard monofocal type on the optical bench

在光学平台上对一种新型疏水性丙烯酸酯增强型单焦点人工晶状体与其标准单焦点类型进行分析

阅读:1

Abstract

INTRODUCTION: The aim of this laboratory study is to objectively analyze the new hydrophobic, acrylic, enhanced monofocal intraocular lens Acunex Quantum (AN6Q) and compare it with the monofocal platform Acunex AN6.  METHODS: Two IOL models were analyzed (Acunex Quantum AN6Q and Acunex AN6, Teleon Surgical, Spankeren, Netherlands), each having the same refractive power of + 22.0 D, on the optical bench with the OptiSpheric IOL PRO 2. The measurements followed the guidelines of the International Standard Organization with following parameters: ISO 2 cornea (+ 0,28 µ), ISO 11979/2, lens placement in situ in NaCl with 35° temperature, 546 nm and selection of different aperture sizes (3.0 mm vs 4.5 mm). The aberrations of each IOL were evaluated by the WaveMaster IOL 2, a high-resolution Shack-Hartmann sensor in reverse projection setup. An in-situ model eye was used according to ISO 11979 in NaCl (n = 1.337) with 546 nm, mask width 4.51. Zernike polynomials up to 10th order were determined by means of the measured wavefront that describe the optical properties of the IOL. RESULTS: Through frequency modulation transfer function (mean) at 50 lp/mm (AN6Q/AN6 centered) was 0.687/0.731 (3.0 mm aperture) and 0.400/0.509 (4.5 mm aperture). The SR (mean) was 0.592/0.809 (3.0 mm) and 0.332/0.372 (4.5 mm). The MTF (mean) at 50 lp/mm (AN6Q/AN6 decentered by 1 mm) was 0.413/0.478 (3.0 mm) and 0.257/0.229 (4.5 mm). The SR (mean) was 0.393/0.404 (3.0 mm) and 0.183/0.212 (4.5 mm). The MTF (mean) at 50 lp/mm (AN6Q/AN6 tilted by 5°) was 0.508/0.710 (3.0 mm) and 0.337/0.513 (4.5 mm). The SR (mean) was 0.508/0.760 (3.0 mm) and 0.235/0.2372 (4.5 mm). AN6Q showed MTF peak of 0.55 with an enlarged depth of power of about 2.5 D and two cusps in the MTF curve. The spherical aberration Z 4-0 was about -0.21 µm and the secondary spherical aberration Z 6-0 was about 0.16 µm. No other relevant aberration showed up. CONCLUSION: The new, enhanced monofocal AN6Q provides an extended range of focus with only slight decrease in contrast quality. Both types of the hydrophobic, acrylic Acunex IOL platform have its particular advantages in clinical settings and therefore its importance, respectively.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。