Reduced CD38 expression on CD34+ cells as a diagnostic test in myelodysplastic syndromes

CD34+细胞上CD38表达降低可作为骨髓增生异常综合征的诊断指标

阅读:1

Abstract

Diagnosis of myelodysplastic syndrome can be difficult especially in cases with a low blast count and a normal karyotype. Flow cytometry has been used to distinguish myelodysplastic syndrome from non-clonal cytopenias. No one single simple flow cytometric parameter has been proposed to be diagnostic of myelodysplastic syndrome. We have studied samples from 100 myelodysplastic syndrome patients and as control samples; 70 non-clonal cytopenias, 5 subjects with normal hematology, 31 patients with acute myeloid leukemia and 11 with chronic myelomonocytic leukemia or myeloproliferative disorder. We show that reduced relative mean fluorescence of CD38 below a threshold value on CD34(+) cells diagnosed low-grade myelodysplastic syndrome with 95% sensitivity (95% confidence interval, 87-99%) and 92% specificity (95% confidence interval, 82-97%). This simple flow cytometric test may be of value in the routine clinical diagnosis of myelodysplastic syndrome, especially in cases with a low blast count and normal karyotype.