Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols

超快速乳腺磁共振成像的机构差异:比较不同患者群体和对比剂注射方案下的压缩感知和视图共享技术

阅读:1

Abstract

PURPOSE: To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols. METHODS: UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis. RESULTS: Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39). CONCLUSION: Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。