Surface area-volume relationships for the mastoid air cell system and tympanum in adult humans: Implications for mastoid function

成人乳突气房系统和鼓室的表面积-体积关系:对乳突功能的影响

阅读:1

Abstract

CONCLUSIONS: The middle ear (ME) surface area/volume ratio (SA/V) is greater than that of the tympanum. The rate of ME pressure decrease is proportional to the ME SA/V. The mastoid air-cell system (MACS) will not function as an ME gas reserve unless the blood perfusion/surface area is much greater for the tympanum than the MACS and decreases as MACS volume increases. OBJECTIVE: To measure the MACS and tympanum surface areas and volumes and ascertain whether the MACS could function as an ME gas reserve. METHODS: Twenty adult subjects with a wide range of MACS volumes underwent CT of their MEs. The left and right surface areas and volumes of the tympanum and MACS were reconstructed and entered into a simple perfusion-limited model of transmucosal gas exchange. In this model the MACS would be a gas reserve if ME SA/V was less than the tympanum SA/V or equivalently, if their ratio was less than a critical value of 1. RESULTS: Both MACS and tympanum SA were linearly related to their volumes. MACS SA/V and the ME SA/V were significantly greater than those for the tympanum. Inputting the measured values into the model yielded a critical value of 1.4, which was significantly greater than 1.