Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review

双动髋臼杯是初次全髋关节置换术和翻修全髋关节置换术的可靠选择吗?一项系统性综述

阅读:1

Abstract

Background: Instability is a common complication following total hip arthroplasty (THA). The dual mobility cup (DMC) allows a reduction in the dislocation rate. The goal of this systematic review was to clarify the different uses and outcomes according to the indications of the cemented DMC (C-DMC). Methods: A systematic review was performed using the keywords "Cemented Dual Mobility Cup" or "Cemented Tripolar Cup" without a publication year limit. Of the 465 studies identified, only 56 were eligible for the study. Results: The overall number of C-DMC was 3452 in 3426 patients. The mean follow-up was 45.9 months (range 12-98.4). In most of the cases (74.5%) C-DMC was used in a revision setting. In 57.5% DMC was cemented directly into the bone, in 39.6% into an acetabular reinforcement and in 3.2% into a pre-existing cup. The overall dislocation rate was 2.9%. The most frequent postoperative complications were periprosthetic infections (2%); aseptic loosening (1.1%) and mechanical failure (0.5%). The overall revision rate was 4.4%. The average survival rate of C-DMC at the last follow-up was 93.5%. Conclusions: C-DMC represents an effective treatment option to limit the risk of dislocations and complications for both primary and revision surgery. C-DMC has good clinical outcomes and a low complication rate.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。