Correlations between 3D preoperative planning and postoperative reduction in the osteosynthesis of distal humeral fractures

3D术前规划与肱骨远端骨折内固定术后复位的相关性

阅读:1

Abstract

BACKGROUND: Three-dimensional preoperative planning has been applied to the osteosynthesis of distal humerus fractures. The present study investigated the correlations between 3D preoperative planning and postoperative reduction for the osteosynthesis of distal humerus fractures using 3D parameters. METHODS: Twenty-three elbows of 23 distal humerus fracture patients who underwent osteosynthesis with three-dimensional preoperative planning were evaluated. 3D images of the distal humerus were created after taking preoperative CT scans of the injured elbow. Fracture reduction, implant selection, and placement simulations were performed based on 3D images. Postoperative CT images were taken 1 month after surgery. Correlations were evaluated with preoperative plans and postoperative 3D images. The longitudinal axis and coordinates of the humerus were defined on the 3D images. The coronal angle (CA) was defined as the angle formed by the long axis and the line connecting the medial and lateral margins of the trochlea of the humerus on a coronal plane image. The sagittal angle (SA) was defined as the angle formed by the long axis and the line connecting the top of the lateral epicondyle and the center of the humeral capitellum on a sagittal plane image. The axial angle (AA) was defined as the angle between the sagittal plane and the line connecting the medial and lateral margins behind the trochlea of the humerus. The intraclass correlation coefficients (ICC) of each measurement value were assessed between preoperative planning and postoperative images. RESULTS: Preoperative planning and postoperative measurement values were CA: 85.6 ± 5.9°/85.8 ± 5.9°, SA: 140.9 ± 8.5°/139.4 ± 7.9°, and AA: 84.0 ± 3.1°/82.6 ± 4.9°, respectively. ICCs were CA: 0.75 (P < 0.01), SA: 0.78 (P < 0.01), and AA: 0.34 (P < 0.05), respectively. CONCLUSIONS: The 3D preoperative planning of distal humeral fractures achieved the good correlations of coronal and sagittal angles, but the relatively poor correlation of the axial angle. This may be attributed to an inability to assess the rotation angle during surgery. We propose the measurement indices shown in the present study as a three-dimensional evaluation index for distal humerus fractures. TRIAL REGISTRATION: Registered as NCT04349319 at ClinicalTrials.gov.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。