A prospective, randomized evaluation of the effect of silver impregnated subcutaneous cuffs for preventing tunneled chronic venous access catheter infections in cancer patients

一项前瞻性随机研究评估了银浸渍皮下套管预防癌症患者隧道式慢性静脉通路导管感染的效果

阅读:1

Abstract

OBJECTIVE: This study was performed to evaluate the effect of a silver-impregnated cuff on the incidence of catheter-related bacteremia/fungemia or tunnel tract infection in cancer patients with chronic dual-lumen tunneled venous access catheters. SUMMARY BACKGROUND DATA: Infection is a frequent and potentially life-threatening complication of tunneled chronic cuffed silastic central venous access catheters in cancer patients. Recent experience with antimicrobial silver-impregnated cuffs placed on nontunneled percutaneously inserted central venous catheters suggests that such a cuff may render the catheter less prone to infection. METHODS: The authors prospectively randomized 200 cancer patients to receive either a dual-lumen 10 French tunneled cuffed silastic central venous access catheter or the same catheter with a second more proximal subcutaneous silver-impregnated cuff. All patients then were followed prospectively for infectious morbidity until the device was removed or the patient died. RESULTS: The hazard rate for infection/day (95% confidence limits) was 0.0022 (0.0015 to 0.0030) for standard catheters compared with 0.0027 (0.0019 to 0.0037) for catheters with silver-impregnated cuffs (p = not significant). Regression analysis of infection-free interval of both catheter types shows no difference over the lifetime of catheter as well as the over the first 48 days after insertion. CONCLUSIONS: The study indicated no effect of a silver-impregnated cuff in decreasing the incidence of catheter-related bacteremias/fungemias, tunnel infections, or the spectrum of causative microorganisms involved in cancer patients with tunneled chronic venous access catheters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。