Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method

使用一种新型半自动分割方法,对从 OAI MR 图像集中分割出的膝关节软骨体积进行测量,并评估其观察者内和观察者间的重复性。

阅读:1

Abstract

OBJECTIVE: We developed a semi-automated method based on a graph-cuts algorithm for segmentation and volumetric measurements of the cartilage from high-resolution knee magnetic resonance (MR) images from the Osteoarthritis Initiative (OAI) database and assessed the intra- and inter-observer reproducibility of measurements obtained via this method. DESIGN: MR image sets from 20 subjects of varying Kellgren-Lawrence (KL) grades (from 0 to IV) on fixed flexion knee radiographs were selected from the baseline double-echo and steady-state (DESS) knee MR images in the OAI database (0.B.1 Imaging Data set). Two trained radiologists independently performed the segmentation of knee cartilage twice using the semi-automated method. The volumes of segmented cartilage were computed and compared. The intra- and inter-observer reproducibility were determined by means of the coefficient of variation (CV%) of repeated cartilage segmented volume measurements. The subjects were also divided into the low- (0, I or II) and high-KL (III or IV) groups. The differences in cartilage volume measurements and CV% within and between the observers were tested with t tests. RESULTS: The mean (+/-SD) intra-observer CV% for the 20 cases was 1.29 (+/-1.05)% for observer 1 and 1.67 (+/-1.14)% for observer 2, while the mean (+/-SD) inter-observer CV% was 1.31 (+/-1.26)% for session 1 and 1.79 (+/-1.72)% for session 2. There was no significant difference between the two intra-observer CV%'s (P=0.272) and between the two inter-observer CV%'s (P=0.353). The mean intra-observer CV% of the low-KL group was significantly smaller than that for the high-KL group for observer 1 (0.83 vs 1.86%: P=0.025). The segmentation processing times used by the two observers were significantly different (observer 1 vs 2): (mean 49+/-12 vs 33+/-6min) for session 1 and (49+/-8 vs 32+/-8min) for session 2. CONCLUSION: The semi-automated graph-cuts method allowed us to segment and measure cartilage from high-resolution 3T MR images of the knee with high intra- and inter-observer reproducibility in subjects with varying severity of OA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。