Anatomic measurements of cerebral venous sinuses in idiopathic intracranial hypertension patients

特发性颅内高压患者脑静脉窦的解剖测量

阅读:1

Abstract

PURPOSE: Magnetic resonance venography (MRV) has not been validated in pre-operative planning of the dural venous sinus stenting (VSS) among idiopathic intracranial hypertension (IIH) patients. We aim to prospectively evaluate dural venous sinus measurement in IIH patient population on two-dimensional time-of-flight (2D-TOF) MRV and Three-dimensional contrast-enhanced (3D-CE) MRV acquisitions and compare them against real-time endoluminal measurements with intravascular ultrasound (IVUS), served as the reference. MATERIALS AND METHODS: The study has been approved by the Weill Cornell Medicine institutional review board. All patients signed written informed consent approved by IRB. Prospective evaluation of forty-five consecutive IIH patients treated with VSS at our institution were evaluated. Patients with pre-stent magnetic resonance venography (MRV) ≤ 6-months of VSS and intravascular ultrasound (IVUS) during VSS constituted the study population. Maximum diameter (in mm), Area (in cm2) and Perimeter (in cm) were measured at posterior 1/3rd of superior sagittal sinus (SSS), proximal transverse sinus (PTS), proximal sigmoid sinus (PSS) and mid sigmoid sinus (MSS) on 2D-TOF-MRV, 3D-CE-MRV and IVUS. Statistical analysis performed using box and whisker plots, Bland-Altman analysis and paired sample t-test. RESULTS: Twenty (n = 20) patients constituted our study population. The mean age was 30±11 years (7-59 years) and 18 out of 20 were female patients. Mean weight and BMI (range) were 86.3±18.3 kilograms (30.8-107.5 kgs) and 32.9±6.8 kg/M2 (16.4-48.3kg/M2) respectively. The CE-MRV significantly oversized the cerebral venous sinuses compared to TOF-MRV (Dmax: +2.0±1.35 mm, p<0.001; Area: +13.31±10.92 mm2, p<0.001 and Perimeter: +4.79±3.4 mm, p<0.001) and IVUS (Dmax: +1.52±2.16 mm, p<0.001; Area: +10.03±21.5 mm2, p<0.001 and Perimeter: +4.15±3.27 mm, p<0.001). The TOF-MRV sinus measurements were in good agreement with the IVUS measurements with no significant variation (Dmax: +.21±2.23 mm, p = 0.49; Area: +2.51±20.41mm2, p = 0.347 and Perimeter: +.001±1.11 mm, p = 0.991). CONCLUSION: We report baseline cerebral venous sinus measurements (maximum diameter, area and perimeter) in patients with idiopathic intracranial hypertension. In our experience, TOF-MRV is a reliable representation of endoluminal cerebral venous sinus dimensions, and CE-MRV measurements reflected an overestimation of the endoluminal sinus dimensions when compared against the real time IVUS measurements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。