Abstract
Surface electrical stimulation is currently used in therapy for swallowing problems, although little is known about its physiological effects on neck muscles or swallowing. Previously, when one surface electrode placement was used in dysphagic patients at rest, it lowered the hyolaryngeal complex. Here we examined the effects of nine other placements in normal volunteers to determine 1) whether movements induced by surface stimulation using other placements differ, and 2) whether lowering the hyolaryngeal complex by surface electrical stimulation interfered with swallowing in healthy adults. Ten bipolar surface electrode placements overlying the submental and laryngeal regions were tested. Maximum tolerated stimulation levels were applied at rest while participants held their mouths closed. Videofluoroscopic recordings were used to measure hyoid bone and subglottic air column (laryngeal) movements from resting position and while swallowing 5 ml of liquid barium, with and without stimulation. Videofluoroscopic recordings of swallows were rated blind to condition using the National Institutes of Health-Swallowing Safety Scale. Significant (P < 0.0001) laryngeal and hyoid descent occurred with stimulation at rest. During swallowing, significant (P