Biomimetic urine flow control can preserve bladder function in patients with indwelling catheterization

仿生尿流控制可以保护留置导尿患者的膀胱功能

阅读:1

Abstract

For patients with long-term indwelling catheterization, bladder function will be affected. It is necessary to explore whether biomimetic urine flow control (BUFC) can improve bladder function in patients undergoing indwelling catheterization. A retrospective, data-only, cohort study was carried out. The patients admitted to the intensive care unit, who had retained catheter and been continuously using a urodynamic monitoring system for over 30 days were selected. They were divided into 2 groups based on whether they were using BUFC function. The urodynamic monitoring data of the 2 groups were compared and analyzed. A total of 30 patients were included in the final analysis, including 15 in the BUFC group and 15 in the unobstructed group. The Urinary Volume and maximal urinary flow rate of the unobstructed group showed a continuous downward trend, while the BUFC group remained stable, and there was a statistical difference (P < .05) between the 2 groups since day 20. The bladder ultrasound imaging showed that the bladder volume of the BUFC group did not decrease significantly on the 30th day. BUFC technology, which provided by a urodynamic monitoring system, has potential protective effects of the bladder function after indwelling catheterization.