Fouling and Mitigation Behavior of Foulants on Ion Exchange Membranes with Surface Property in Reverse Electrodialysis

反向电渗析中表面性质对离子交换膜污染及污染物抑制行为的影响

阅读:1

Abstract

In this study, two different types of ion exchange membranes are used to investigate the tendency of membrane fouling with respect to surface roughness and hydrophilicity. Commercially available membranes reinforced by electrospun nanofiber have rough and hydrophilic surfaces, and lab-made pore-filling membranes exhibit a smooth and hydrophobic surface. Three different organic surfactants (i.e., cationic, anionic and non-ionic surfactants) are chosen as foulants with similar molecular weights. It is confirmed that membrane fouling by electrical attraction mainly occurs, in which anionic and cationic foulants influence anion and cation exchange membranes, respectively. Thus, less fouling is obtained on both membranes for the non-charged foulant. The membranes with a rough surface show a higher fouling tendency than those with a smooth surface in the short-term continuous fouling tests. However, during the cyclic operations of fouling and mitigation of the commercially available membranes, the irregularities of a rough membrane surface cause a rapid increase in electrical resistance from the beginning of fouling due to excessive adsorption on the surface, but the fouling is easily mitigated due to the hydrophilic surface. On the other hand, the membranes with a smooth surface show alleviated fouling from the beginning of fouling, but the irreversible fouling occurs as foulants accumulate on the hydrophobic surface which causes membrane fouling to be favorable.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。