Ferrocene probe-assisted fluorescence quenching of PEI-carbon dots for NO detection and the logic gates based sensing of NO enabled by trimodal detection

二茂铁探针辅助荧光猝灭 PEI-碳点用于 NO 检测以及基于逻辑门的三峰检测 NO 传感

阅读:15
作者:S Priya, Sheela Berchmans

Abstract

Our research demonstrates the effectiveness of fluorescence quenching between polyethyleneimine functionalised carbon dots (PEI-CDs) and cyclodextrin encapsulated ferrocene for fluorogenic detection of nitric oxide (NO). We confirmed that ferrocene can be used as a NO probe by observing its ability to quench the fluorescence emitted from PEI-CDs, with NO concentrations ranging from 1 × 10-6 M to 5 × 10-4 M. The photoluminescence intensity (PL) of PEI-CDs decreased linearly, with a detection limit of 500 nM. Previous studies have shown that ferrocene is a selective probe for NO detection in biological systems by electrochemical and colorimetric methods. The addition of fluorogenic NO detection using ferrocene as a probe enables the development of a three-way sensor probe for NO. Furthermore, the triple mode NO detection (electrochemical, colorimetric, and fluorogenic) with ferrocene aids in processing sensing data in a controlled manner similar to Boolean logic operations. This work presents key findings on the mechanism of fluorescence quenching between ferrocene hyponitrite intermediate and PEI-CDs, the potential of using ferrocene for triple channel NO detection as a single molecular entity, and the application of logic gates for NO sensing.